Multec-M (14 SE / C 14 SE / C 16 SE) F2: TROUBLE CODE
| Trouble Code | Information Sensor Cause of Fault | Remedy in F0:DATA LIST No. | Trouble Code Storage when ... |
|---|---|---|---|
| 45 | RICH EXHAUST | 17, 18, 19 | · Engine running at idle speed |
· Coolant temperature higher than 75 °C/167 °F
· Following trouble codes not stored: 33, 34
· Loop closed
· Throttle valve aperture greater than 0 %
· The fault is recognized by the control unit if the oxygen sensor voltage is greater than 757 mV for longer than 17 s.
If trouble code 45 was recognized, the control unit takes 450 mV as replacement voltage
(oxygen sensor control switched off).
Note: