Multec-S Multiple Fuel Injection (C 16 XE) F2:TROUBLE CODE TABLE
Trouble
| Code |
Information Sensor
| Cause of Fault | Remedy in |
F0:DATA LIST
| No. | ||
|---|---|---|
| Trouble Code Storage when ... | ||
| Remarks | ||
| 68 | MASS AIR FLOW | |
| SENSOR FREQUENCY | 03 | · Ignition ON |
· Following trouble codes not stored: 19 and 92
· Fault 68 is stored if an air mass smaller than 4.5 kg/h is recognized for at least 5 s.
Note:
The internally calculated value for the air mass is taken as the replacement value.