Multec-S Multiple Fuel Injection (C 16 XE) F2:TROUBLE CODE TABLE
Trouble
| Code |
Information Sensor
| Cause of Fault | Remedy in |
F0:DATA LIST
| No. | |
|---|---|
| Trouble Code Storage when ... | |
| Remarks | |
| 67 | MASS AIR FLOW |
SENSOR RANGE
| 03 | · Following trouble codes are not stored: 19, 21, 22 |
· The control unit compares the information supplied by the hot film mass air flow meter with the values calculated by the control unit. If a deviation of more than 30 % is recognized, the conditions for setting the fault are fulfilled.
· Fault 67 is stored and the internally calculated values for the air mass are taken as the replacement value.