Multec (X 12 SZ / X 16 SZ) F0: DATA LIST
| No. | TECH 1 Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 36 | DIAG. REQUEST | Ignition ON | INACTIVE | ||
| 12V | - | D 8 / D 1 | |||
| Trouble - shooting: | Nominal Value: | Cause of Fault: |
(If nominal value is not attained)
· Ignition OFF
· Measure voltage:
from: diagnostic plug Ter. "B"
to: ground
· Ignition ON
| INACTIVE 12V | |
|---|---|
| greater than 11 V | · Short circuit in wiring harness |
from: diagnostic excitation lead "B" in diagnostic plug
| to: ground |
· Carry out check according to table 1.