Multec-S X 14 XE / X 16 XE (L) F0:DATA LIST
| No. | TECH 1 Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 34 | ENGINE SPEED | ||||
| Ignition ON | |||||
| Engine running at idle speed, operating temperature | 0 rpm | ||||
| 35, 19 | B14 / A16 | ||||
| X 14 XE MT: | 850 to 950 rpm | ||||
| X 16 XE MT: | 825 to 975 rpm | ||||
| X 16 XEL MT: | 700 to 1000 rpm | ||||
| X 14 XE AT: | |||||
| Selector lever position "P" | |||||
| 850 to 950 rpm | |||||
| X 14 XE AT: | |||||
| Selector lever position "D" | |||||
| 725 to 825 rpm |