MULTEC Central Fuel Injection (12 NZ, C 12 NZ, C 14 NZ) F2:TROUBLE CODE TABLE
Trouble
| Code |
Information Sensor
| Cause of Fault | Remedy in |
F0:DATA LIST
| No. | |
|---|---|
| Trouble Code Storage when ... | |
| Remarks | |
| 13 | O2 SENSOR |
OPEN CIRCUIT
| 08 |
09
10
11
| · Engine running for at least 40 s |
· Coolant temperature higher than 85 °C/185 °F
· Throttle valve aperture greater than 6 %
· Following trouble codes not stored: 21, 22
· The fault is recognized by the control unit if the oxygen sensor voltage is in the range 350 to 550 mV for longer than 12 s
(lead interruption, oxygen sensor defective).
If trouble code 13 was recognized, the control unit takes
450 mV as replacement voltage
(oxygen sensor control switched off).
Note:
If the oxygen sensor is wrapped in aluminium foil, remove the foil. Then delete trouble code. If trouble code is set again, start trouble-shooting.