Multec- S X 14 XE / X 16 XE (L) F0:DATA LIST
| No. | TECH 1 Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 40 | DES. IDLE DRIVE | Vehicles with AT: |
Ignition ON
Engine running at idle speed, operating temperature
| Nominal idle speed for selector lever position "R", "D", "3", "2", and "1" has not been changed (basic setting after control unit reset) | - | |
|---|---|---|
| X 14 XE AT: |
Nominal idle speed for selector lever position "R", "D", "3", "2", and "1" has been programmed.
Note:
The nominal engine speed is a programmable value.
If F0:DATA LIST no.: 41 is ACTIVE, the nominal engine speed has been reprogrammed.
| If F0:DATA LIST no.: 41 is INACTIVE, the nominal engine speed has not been altered or the control unit has been reset. In this case, ignore the TECH 1 display. A randomly selected value will be displayed. | 775 rpm | |
|---|---|---|
| The nominal engine speed set in F6:Miscellaneous Tests, F0:Adjustments must appear in the display | ||
| Notes on Trouble-shooting: | Nominal Value: | Cause of fault: |
(If nominal value is not attained)
Not at start of production MY'95
· Select TECH 1 menu:
F6:MISC. TESTS,
F0:ADJUSTMENTS
Program new idle speed 825 rpm.
· TECH 1 data list no. 41
IDLE ADJ. DRIVE
· TECH 1 data list no. 40
DES. IDLE DRIVE
| ACTIVE |
825 rpm
| · Check control unit calibration, see field remedy measures |
· Select TECH 1 menu:
F6:MISC. TESTS,
F1:ECU RESET
· TECH 1 data list no. 41
IDLE ADJ. DRIVE
· TECH 1 data list no. 40
| DES. IDLE DRIVE | INACTIVE |
|---|---|
| 775 rpm | · Check control unit calibration, see field remedy measures |