| No. | TECH 1 | Checking Conditions | Nominal Values | Trouble | Terminal |
|---|---|---|---|---|---|
| Display | Codes | ||||
| 12 | 02 BLM ENABLE* | Ignition ON | INACTIVE | 13, 35, | INTERNAL |
| 44, 45 | |||||
| Engine at idle speed at 1500 rpm and | |||||
| is at operating temperature | |||||
| (temperature > 80 °C/176 °F) | ACTIVE | ||||
| (Adjust engine speed with TECH 1 mode | |||||
| "F7", submode "F0" ) |
Trouble-shooting: Nominal Value: Cause of Fault:
(If nominal value is not attained)
If all other checking values of the FO:DATA LIST lie within the given tolerances, the vehicle performs perfectly and the customer has no further complaints, do not carry out any further measures.
Otherwise, replace the control unit.
* Throttle valve must be closed. Coolant temperature > 80 °C/176 °F