Contents Wiring diagrams Section: Fuel Injection Systems All sections

F0:Data List - Test Step 25 A/c Relay Opel Corsa B

Multec - S (C 16 XE) F0:DATA LIST

No.TECH 1 DisplayConditions for CheckingNominal ValueTrouble CodesTerminal
25A / C RELAYEngine running at idle speed, at operating temperature93E 4
AC switch OFFINACTIVE 12 V
AC switch ONACTIVE 0 V
Vehicle without ACINACTIVE 12 V
Trouble - shooting:Nominal Value:Cause of Fault:

(If nominal value is not attained)

· Test steps 23 and 24:OK· Carry out test steps 23 and 24

· Ignition OFF

· Disconnect relay K 60

· Measure voltage:

from: relay socket K 60 Ter. 86

to: ground

less than 0.1 V· Short circuit to voltage

from: relay socket K 60 Ter. 86

to: fuse F 21
· Ignition ONgreater than 11 V· Fuse F 21 defective

· Lead interruption

from: fuse F 21

to: relay socket Ter. 86

· Short circuit to ground

from: fuse F 21

to: relay socket Ter. 86

· Ignition OFF

· Disconnect control unit plug K 57

· Bridge relay socket K 60

from: K 60 Ter. 86

to: K 60 Ter. 85

· Measure voltage:

from: control unit K 57 Ter. E 4

to: groundless than 0.1 V· Short circuit to voltage

from: relay socket K 60 Ter. 85

to: control unit K 57 Ter. E 4

· Ignition ON

· Measure voltage:

from: control unit K 57 Ter. E 4

to: ground

greater than 11 V· Lead interruption

from: relay socket K 60 Ter. 85

to: control unit K 57 Ter, E 4

· Check plug X 4

· Short circuit to ground

from: relay socket K 60 Ter. 85

to: control unit K 57 Ter. E 4

· Ignition OFF

· Remove bridge for relay socket K 60

· Connect relay K 60

· Bridge control unit plug K 57:

from: control unit K 57 Ter. E 4

to: ground

Relay K 60 inactive· Short circuit to ground

from: relay socket K 60 Ter. 85

to: control unit K 57 Ter. E 4

· Ignition ONRelay K 60 active· Lead interruption
from: control unit K 57 Ter. E 4

to: relay socket Ter. 85

· Relay defective

· Check circuit for relay K 60 and compressor relay K 60 acc. applicable Air Conditioning Checking Procedures

see Air Conditioning Checking Procedures· Circuit in relay K 60 defective
· Compressor relay K 60 defective
If nominal values are attained
· Control unit defective