Contents Wiring diagrams Section: Fuel Injection Systems All sections

Checking with Diagnostic Switch KM-640 Opel Corsa B

Checking with Diagnostic Switch KM-640

Diagnostic Switch, Connect

For this, the switch is turned to position "B" and connected to the diagnostic plug (ALDL plug) in the engine compartment.

Trouble Code Readout with Diagnostic Switch KM-640

The excitation line of the MULTEC control unit is short-circuited to ground with KM-640 in the diagnostic switch.

This triggers blink code readout with the ignition switched on. Any trouble codes that may be present are now displayed via the engine telltale.

Important Note!

If the customer reports that the engine telltale had illuminated while driving, and it remains out in the workshop, fault no. 3 is present. I.e. the actual fault is in certain circumstances still present, as the conditions for setting (see Table 2) have been fulfilled, but the fault can no longer be recognized, because the driving conditions have changed so much that they no longer correspond to the conditions described in Table 2. See also remedy in 5.1.7.2: Important Note

Type of Fault No. 2 or No. 3 can only be recognized with TECH 1!

Service Mode with Diagnostic Switch KM-640

The service mode is active when the engine is running and Diagnostic Switch KM-640 is connected to the ALDL plug and turned to position "B". This mode is not supported by TECH 1.

C 12 NZ as of MY '91 and C 14 NZ as of Feb. '91

Operating Method:1.If the oxygen loop is not yet closed, the engine telltale flashes with a frequency of
2.5 Hz.
!!Use only if2.If the oxygen loop is closed, the engine telltale flashes if the control unit at the
no TECH 1input: "oxygen sensor has registered a voltage change from lean to rich or from rich
to lean within the last second.
is available3.If no voltage change has taken place at the oxygen sensor within the last second, the
present actual mixture condition is displayed.
i.e. rich mixture = engine telltale "ON"
lean mixture = engine telltale "OFF"
Remark:In the service mode, the idle engine speed is increased to 1000 rpm and the firing
angle adjusted to 5°.
If the control unit registers a fault in the service mode, it is not filed in the fault
memory.

Only for C 14 NZ up to Feb. '91

Operating Method:1.If the oxygen loop is not yet closed, the engine telltale remains "ON".
!!Use only if2.If the oxygen loop is closed, the engine telltale is "OFF" if the control unit at the
no TECH 1input "oxygen sensor voltage" has registered a voltage change from lean to rich or
is availablefrom rich to lean within the last second.
3.If no voltage change has taken place at the oxygen sensor within the last second, the
present actual mixture condition is displayed.
i.e. rich mixture = engine telltale "ON"
lean mixture = engine telltale "OFF"
Remark:In the service mode, the idle engine speed is increased to 1000 rpm and the firing
angle adjusted to 5°.
If the control unit registers a fault in the service mode, it is not filed in the fault
memory.