Table 2, Multec-S (C 16 XE) F2: TROUBLE CODE
Trouble
| Code | Information Sensor | ||
|---|---|---|---|
| Cause of Fault | Remedy in F0: | ||
| DATA LIST | Trouble Code Storage when... | ||
| 92 | HALL SENSOR CIRCUIT | - | · Ignition ON |
· Engine running
· Following trouble codes not stored: 19
· Engine speed signal is recognized by the control unit
· The control unit has not recognized any pulse from the camshaft sensor at Ter. B 5
· The above conditions must be satisfied for at least 20 crankshaft revolutions