Multec - S (C 16 XE) F0:DATA LIST
| No. | TECH 1 Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 39 | DES. IDLE ADJUST | Engine running at idle speed, at operating temperature | |||
| The nominal engine |
speed set in F6:
Miscellaneous Tests
| F0: Adjustments must appear in the display. | - | - |
|---|---|---|
| Trouble - shooting: | Nominal Value: | Cause of Fault: |
(If nominal value is not attained)
| Note: |
The nominal engine speed can be programmed.
If the F0: DATA LIST No.: 39 is ACTIVE the nominal engine speed has been reprogrammed.
If the F0: DATA LIST No.: 39 is INACTIVE the nominal engine speed has not been altergd or the control unit has been reset. In this case, ignore this TECH 1 display. A randomly selected value is displayed.
· In the TECH 1 menu F6: ADJUSTMENTS, program new idle speed 1000 rpm.
· TECH 1 display: IDLE ADJUST
· TECH 1 display: DES. IDLE ADJUST
| ACTIVE | |
|---|---|
| 1000 rpm | · Control unit defective |
· In the TECH 1 menu F6: ECU RESET
· TECH 1 display: IDLE ADJUST
· TECH 1 display: DES. IDLE ADJUST
| INACTIVE | |
|---|---|
| 900 rpm | · Control unit defective |