Multec - S (C 16 XE) F0: DATA LIST
| No. | TECH 1 Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 16 | O2 BLM PART REF. | Engine running at idle speed, at operating temperature | approx. 128 steps | - | - |
| Trouble - shooting: | Nominal Value: | Cause of Fault: |
(If nominal value is not attained)
· Compare TECH 1 value for test step 14 O2 BLM CELL CONT, with O2 BLM PART REF.
| Deviation of both values: less than 15 % | · Engine takes in dead air | |
|---|---|---|
| · Control unit defective |
Note:
In test step 14, the long - term memory contents of BLM cell 16 at idle speed are indicated.
O2 BLM PART REF. on the other hand displays the long - term memory contents of cell 10.
In this test, therefore, the BLM cell content of the idle speed cell is always compared with a particular partial load cell.