Table 2, Multec-S (C 16 XE) F2: TROUBLE CODE
Trouble
| Code | Information Sensor | ||
|---|---|---|---|
| Cause of Fault | Remedy in F0: | ||
| DATA LIST | Trouble Code Storage when... | ||
| 67 | MASS AIR FLOW SENSOR FREQUENCY | 03 | · Ignition ON |
· Following trouble codes not stored: 19 and 92
· Fault 68 is stored, if for at least 5 s the air mass is ecognized to be less than 4.5 kg / h
Note: