Home/Opel/Corsa/Opel Corsa B (1993-2000)/Repair manual/Fuel Injection Systems/F0:Data List - Test Step 29 A/c Informat. Sw
Contents Wiring diagrams Section: Fuel Injection Systems All sections

F0:Data List - Test Step 29 A/c Informat. Sw Opel Corsa B

Multec-M (14 SE / C 14 SE / C 16 SE) F0:DATA LIST

No.TECH 1 DisplayConditions for CheckingNominal ValueTrouble CodesTerminal
29A/C INFORMAT. SWIgnition ON

AC switch ON

AC switch OFF

INACTIVE 0V

ACTIVE 12V

INACTIVE 0V-D 5 / D 1
Trouble-shooting:Nominal Value:Cause of Fault:
(If nominal value is not attained)

· Ignition ON

· Disconnect plug from combi-pressure-switch S 20 of the AC system (4 pin)

· Measure voltage:

from: wiring harness plug S 20 Ter. 1

to: ground

· AC switch S 101 OFF

· AC switch S 101 ON

0 volts

greater than 11 volts· Lead interruption

from: battery Ter. 30

to: AC switch S 101 Ter. 1

· AC switch S 101 defective

· Lead interruption

from: AC switch S 101

to: wiring harness plug X 7 Ter. C / X 6 Ter. 57

· Lead interruption

from: wiring harness plug X 7 Ter. C / X 6 Ter. 57

to: wiring harness plug S 20 Ter. 1

· Lead interruption

from: ignition lock Ter. 15 A

to: relay K 6

· Relay K 6 or fuse F 14 defective

· Ignition OFF

· Disconnect wiring harness plug X 8 / X 4

· Bridge X 8:

from: X 8 / X 4 Ter. 3 (at the control unit side)

to: battery voltage Ter. 30

· Ignition ON

ACTIVE 12V

· Lead interruption

from: control unit plug K 57, K 91 Ter. D 5

to: plug X 8 / X 4 Ter. 3

· Control unit defective

· Ignition OFF

· Connect wiring harness plug X 8 / X 4

· Bridge plug at combi-pressure-switch S 20

from: wiring harness plug S 20 Ter. 1

to: wiring harness plug S 20 Ter. 2

· Ignition ON

· AC switch ON

· Lead interruption

from: wiring harness plug S 20 Ter. 2

to: plug X 7 Ter. A / X 6 Ter. 54

· Lead interruption

from: plug X 7 Ter. A / X 6 Ter. 54

to: plug X 8 Ter. 3 / X 4 Ter. 3

ACTIVE 12V

Fan operating

· Short circuit in the wiring harness

from: wiring harness plug S 20 Ter. 2

to: ground

· Coil in relay K 26 (fan) defective Relay is causing short circuit to ground