Table 2, Multec-S (C 16 XE) F2: TROUBLE CODE
Trouble
| Code | Information Sensor | ||
|---|---|---|---|
| Cause of Fault | Remedy in F0: | ||
| DATA LIST | Trouble Code Storage when... | ||
| 67 | MASS AIR FLOW SENSOR RANGE | 03 | · Following trouble codes are not stored: 19,21,22 |
· The control unit compares the information supplied by the hot wire mass air flow meter with the value computed by the control unit. If then a deviation greater than 30 % is recognized, the trouble code setting condition is satisfied