Multec - S (C 16 XE) F0: DATA LIST
| No. | TECH 1 Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 13 | O2 BLM CELL NO. | Engine running at idle speed, at operating temperature | 16 | 13,44,45 | - |
| Engine running in partial load range, at operating temperature | |||||
| 0 to 15 |
· This test step indicates the block learn method cell occupied by the system. If an incorrect block learn method cell number is indicated, then check the following causes of faults:
| Trouble - shooting: | Nominal Value: | Cause of Fault: |
(If nominal value is not attained)
| · Possible causes of fault | · Engine running time too brief (engine cold) |
· Coolant temperature sensor P 30 defective
· Throttle valve potentiometer P 34 defective
· Oxygen sensor P 32 defective
· Mass air flow meter P 52 defective
· If the systems designated by the cause of fault do not register as defective, replace the control unit
| · Control unit defective |