F7: PROGRAMMING

No.TECH 1-DisplayConditions for CheckingNominal ValueTrouble CodesTerminal
01SELECT PROGRAM. INIT. ECUIgnition ON

Engine OFF

When asked whether the correct control unit is installed, proceed according to the following information:
At present, the Omega - B with the X 25 XE engine is equipped with the following control unit:

Opel Part No.: 90457097

Alpha Code: PREXISTING ECU

PART - NO / AC

XXXXXXX / XX

OKAY?

INIT. - CODING

F0: RESET

F1: CHANCE
The Omega - B with the X 30 XE engine is equipped with the following control unit at present:

Opel Part No.: 90457098

Alpha Code: PS
If the question is answered with "YES", TECH 1 shows the sub - menu on the right:INIT. - CODING

F0: RESET

F1: CHANCE
Selection of the menu item F0: RESET programs the control unit with the basic application.

Note that, among other adjustments, this resets the idle speed to its basic values. Therefore, if the F0: RESET function is used for an already programmed control unit or adjusted engine, then call up the following TECH 1 function and make / check the relevant adjustment:

Table 6 F6: ECU ADJUSTMENT, test step 01

Note:

Menu item F1: Change is intended for later applications.

INIT. - CODING
F0: RESET
If the display on the right appears after programming is completed, programming was successful.PROGRAMMING ECU INIT. - CODING SUCCESSFUL!
If the display on the right appears after programming is completed, a fault has occurred during programming. Carry out the following measures consecutively:

· Repeat programming;

· Carry out TECH 1 self - test;

· Check TECH 1 cable for damaged insulation and shielding;

· Repeat programming with new Motronic control unitPROGRAMMING ECU INIT. - CODING FAILED!
Notes on Trouble - shooting:Nominal Value:Cause of Fault:

· See F0: DATA LIST, test steps 45 to 56

· See Table 1; ALDL Diagnostic Plug, Voltage Supply and Auxiliary Fan for Electronics Box, Check Test steps 1 to 10