F7: PROGRAMMING
| No. | TECH 1-Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 01 | SELECT PROGRAM. INIT. ECU | Ignition ON |
Engine OFF
| When asked whether the correct control unit is installed, proceed according to the following information: | |
|---|---|
| At present, the Omega - B with the X 25 XE engine is equipped with the following control unit: |
Opel Part No.: 90457097
| Alpha Code: PR | EXISTING ECU |
PART - NO / AC
XXXXXXX / XX
OKAY?
INIT. - CODING
F0: RESET
| F1: CHANCE | |
|---|---|
| The Omega - B with the X 30 XE engine is equipped with the following control unit at present: |
Opel Part No.: 90457098
| Alpha Code: PS | ||
|---|---|---|
| If the question is answered with "YES", TECH 1 shows the sub - menu on the right: | INIT. - CODING |
F0: RESET
| F1: CHANCE | |
|---|---|
| Selection of the menu item F0: RESET programs the control unit with the basic application. |
Note that, among other adjustments, this resets the idle speed to its basic values. Therefore, if the F0: RESET function is used for an already programmed control unit or adjusted engine, then call up the following TECH 1 function and make / check the relevant adjustment:
Table 6 F6: ECU ADJUSTMENT, test step 01
Note:
Menu item F1: Change is intended for later applications.
| INIT. - CODING | |||
|---|---|---|---|
| F0: RESET | |||
| If the display on the right appears after programming is completed, programming was successful. | PROGRAMMING ECU INIT. - CODING SUCCESSFUL! | ||
| If the display on the right appears after programming is completed, a fault has occurred during programming. Carry out the following measures consecutively: |
· Repeat programming;
· Carry out TECH 1 self - test;
· Check TECH 1 cable for damaged insulation and shielding;
| · Repeat programming with new Motronic control unit | PROGRAMMING ECU INIT. - CODING FAILED! | |
|---|---|---|
| Notes on Trouble - shooting: | Nominal Value: | Cause of Fault: |
· See F0: DATA LIST, test steps 45 to 56
| · See Table 1; ALDL Diagnostic Plug, Voltage Supply and Auxiliary Fan for Electronics Box, Check Test steps 1 to 10 |