DIGITAL DIESEL ELECTRONICS DDE 2.1 F2: TROUBLE CODE TABLE
| Trouble Code | Information Sensor |
|---|---|
| Cause of Fault | Remedy in |
F0: DATA LIST
| No. | Trouble Code Storage when... | |
|---|---|---|
| 15 | COOLANT TEMP. | |
| VOLTAGE HIGH | 02 | · Coolant temperature lower than - 40 °C / - 40 °F (voltage higher than 4.92 V) |
(short circuit to voltage or circuit interruption)
· Condition must be fulfilled for at least 0.5 s
Replacement values:
· The current fuel temperature is used for fuel quantity allocation and actuation of the exhaust gas recirculation valve.
· 50 °C / 122 °F for preheating
· 50 °C / 122 °F for start of injection
· 130 °C / 266 °F for AC compressor cutoff
Note:
| The sensor may be destroyed by a short circuit to battery. |