Table 2, Digital Diesel Electronics DDE 2.1 F2:TROUBLE CODE TABLE
| Trouble Code | Information Sensor Cause of Fault | Remedy in F0:DATA LIST No. | Trouble Code Storage when... |
|---|---|---|---|
| 16 | FUEL TEMPERATURE VOLTAGE LOW | 03 | · Fuel temperature higher than 130 °C/ 266 °F (voltage lower than 530 mV) |
(short circuit to ground)
· Condition must be fulfilled for at least 0.5 s
Replacement values:
· 60 °C/ 140 °F