Home/Opel/Omega/Opel Omega B (1994-2003)/Repair manual/Fuel Injection Systems/C-03, Control Unit Temperature Sensor Circuit
Contents Wiring diagrams Section: Fuel Injection Systems All sections

C-03, Control Unit Temperature Sensor Circuit Opel Omega B

C-03, Control Unit Temperature Sensor Circuit

C-03, Control Unit Temperature Sensor Circuit
TestWork Order DescriptionNominal Value
T01Check: Short to Voltage of Signal Circuit
Ignition OFF Disconnect wiring harness connector from: S58 Switch - Temperature, Relay Box Measure voltage between the following terminals: S58 Switch - Temperature, Relay Box Wiring Harness Connector Color BRBL 0,75 & Ground Note: Wiring colors: A=RT=Red, B=GE=Yellow, F=SW=Black, M=WS=White, P=BL=Blue, R=GR=Grey, U=GN=Green, X=BR=Brown, Y=VI=Violetless than 0.1 V
Yes: T02No: E04
T02Check: Short to Ground/Interruption of Signal Circuit
Ignition ON Measure voltage between the following terminals: S58 Switch - Temperature, Relay Box Wiring Harness Connector Color BRBL 0,75 & Ground Note: Wiring colors: A=RT=Red, B=GE=Yellow, F=SW=Black, M=WS=White, P=BL=Blue, R=GR=Grey, U=GN=Green, X=BR=Brown, Y=VI=Violetgreater than 5 V
Yes: T03No: E03
T03Check: Circuit Interruption of Ground Circuit
Ignition OFF Measure resistance between the following terminals: S58 Switch - Temperature, Relay Box Wiring Harness Connector Color BRGN 0,75 & Ground Note: Wiring colors: A=RT=Red, B=GE=Yellow, F=SW=Black, M=WS=White, P=BL=Blue, R=GR=Grey, U=GN=Green, X=BR=Brown, Y=VI=Violetless than 2 Ohm
Yes: E01No: E02
C-03, Control Unit Temperature Sensor Circuit
ResultCause Of Fault
E01Defective component: S58 Switch - Temperature, Relay Box
E02Circuit interruption between: S58 Switch - Temperature, Relay Box Wiring Harness Connector Color BRGN 0,75 & Ground Note: Wiring colors: A=RT=Red, B=GE=Yellow, F=SW=Black, M=WS=White, P=BL=Blue, R=GR=Grey, U=GN=Green, X=BR=Brown, Y=VI=Violet
E03Short circuit to ground/interruption of circuit between: K70 Control Unit - Diesel Wiring Harness Connector (wiring harness side) Terminal 36 & S58 Switch - Temperature, Relay Box Wiring Harness Connector Color BRBL 0,75 or Defective component: K70 Control Unit - Diesel
Note: Wiring colors: A=RT=Red, B=GE=Yellow, F=SW=Black, M=WS=White, P=BL=Blue, R=GR=Grey, U=GN=Green, X=BR=Brown, Y=VI=Violet
E04Short circuit to voltage between: K70 Control Unit - Diesel Wiring Harness Connector (wiring harness side) Terminal 36 & S58 Switch - Temperature, Relay Box Wiring Harness Connector Color BRBL 0,75 or Defective component: K70 Control Unit - Diesel
Note: Wiring colors: A=RT=Red, B=GE=Yellow, F=SW=Black, M=WS=White, P=BL=Blue, R=GR=Grey, U=GN=Green, X=BR=Brown, Y=VI=Violet