DIGITAL DIESEL ELECTRONICS DDE 2.1 F2: TROUBLE CODE TABLE
| Trouble Code | Information Sensor |
|---|---|
| Cause of Fault | Remedy in |
F0: DATA LIST
| No. | Trouble Code Storage when... | |
|---|---|---|
| 17 | FUEL TEMPERATURE | |
| VOLTAGE HIGH | 03 | · Fuel temperature lower than - 40 °C / - 40 °F (voltage higher than 4.92 V) |
(short circuit to voltage or circuit interruption)
· Condition must be fulfilled for at least 0.5 s
Replacement values:
· 60 °C / 140 °F
Note:
| The sensor may be destroyed by a short circuit to battery. |