SIMTEC 56.1 F2: TROUBLE CODE TABLE
| Trouble Code | Information Sensor |
|---|---|
| Cause of Fault | Remedy in |
F0: DATA LIST
| No. | Trouble Code Storage when... |
44
| O2 SENSOR |
LEAN EXHAUST
| 26, 27, 28, 29, 30, 31 |
|---|
| · Engine not in operating condition: deceleration fuel cutoff and full load |
· Engine running at idle speed
· Coolant temperature higher than 31 °C / 88 °F
or
· Engine running in load range
Coolant temperature higher than 31 °C / 88 °F
· Oxygen sensor control limit "lean" attained for 10 s
· Controlled canister purge valve closed
· Following trouble codes not stored: 61
· Oxygen sensor heating actuated for 11 s at 100 %
· Conditions must be fulfilled for at least 2.5 s
Effects:
· Oxygen sensor regulation and controlled canister purge valve regulation are blocked
· Controlled canister purge valve is closed