SIMTEC 56.1 F2: TROUBLE CODE TABLE
| Trouble Code | Information Sensor |
|---|---|
| Cause of Fault | Remedy in |
F0: DATA LIST
| No. | Trouble Code Storage when... |
91
| O2 SENSOR |
HEATING VOLTAGE
HIGH
| 26, 27, 28, 29, 30, 31 | · Short circuit to voltage or interruption in circuit |
to control unit terminal 36
· Condition must be fulfilled for at least 5 s
· No fault recognition at a pulse ratio lower than 9.4 %