SIMTEC 56.1 Quick Check F0: DATA LIST
| No. | TECH 1 Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 07 | INTAKE AIR TEMP. | Engine running at idle speed, operating temperature | 10 to 80 °C / | 69, 71 | 6, 19 |
| Ambient temperature higher than 10 °C / 50 °F | 50 to 176 °F | ||||
| 3.0 to 0.5 V |