Contents Wiring diagrams Section: Fuel Injection Systems All sections

F0: Data List - Test Step 27 O2 Sensor Opel Omega B

SIMTEC 56.1 Quick Check F0: DATA LIST

No.TECH 1 DisplayConditions for CheckingNominal ValueTrouble CodesTerminal
27O2 SENSOREngine running at idle speed, operating temperature13, 38, 39, 44, 457, 19, 25, 36
Switch off all consumersVoltage change between less than 400 mV and greater than 3850 mV
Note:
In contrast to the previously familiar Multec and Motronic systems, the voltage to the oxygen sensor in the SIMTEC system alternates in the range from approx. 0 to 5 V.