SIMTEC 56.1 Quick Check F0: DATA LIST
| No. | TECH 1 Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 20 | ENGINE SPEED LIM | Engine running at idle speed, operating temperature | |||
| INACTIVE | - | - | |||
| Depress accelerator pedal to full load stop |
(full throttle)
| ACTIVE | |
|---|---|
| Note: |
Engine speed limitation becomes active at approx. 6600 rpm. To limit the engine speed, the injectors are switched off.
| As the engine speed at which limitation is active is very high, it is difficult to perform the test so that the limitation is activated. |