Home/Opel/Omega/Opel Omega B (1994-2003)/Repair manual/Fuel Injection Systems/Engine Management System Simtec 56.1 Trouble Code Table
Contents Wiring diagrams Section: Fuel Injection Systems All sections

Engine Management System Simtec 56.1 Trouble Code Table Opel Omega B

Trouble Code Table

Trouble CodeInformation SensorCause of Fault
13Oxygen sensorSensor too old / contaminated with lead
14Coolant temperature sensorShort circuit to ground
15Coolant temperature sensorShort circuit to UB / lead fracture
16Knock sensorShort circuit to ground / lead fracture loose fastening bolt / short circuit to UB / control unit defective
19Inductive pulse pick - upShod circuit / lead fracture
21Throttle valve potentiometerShort circuit to UB / lead fracture
22Throttle valve potentiometerShort circuit to ground
23Knock sensorControl unit defective
24Odometer frequency sensorShort circuit / lead fracture
25Injector 1Shod circuit to UB lead fracture
26lnjector 2Short circuit to UB lead fracture
27lnjector 3Short circuit to UB lead fracture
28lnjector 4Short circuit to UB lead fracture
33Final stage,Short circuit to ground
exhaust gas recirculation valve
34Final stage,Short circuit to UB / lead fracture
exhaust gas recirculation valve
37Engine telltaleShort circuit to ground
38Oxygen sensorShort circuit to ground / lead fracture
39Oxygen sensorShort circuit to UB
44Oxygen sensorMixture lean
45Oxygen sensorMixture rich
46Final stage, secondary air pump relayShort circuit to ground
47Final stage, secondary air pump relayShort circuit to UB / lead fracture
48BatteryVoltage too low
49BatteryVoltage too high
52Final stage, engine telltaleShort circuit to UB / lead fracture
53Final stage, fuel pump relayShort circuit to ground
54Final stage, fuel pump relayShort circuit to UB / lead fracture
55Control unitDefective
56Final stage, idle speed stepper motorShort circuit to UB / lead fracture
57Final stage, idle speed stepper motorShort circuit to ground
61Final stage, controlled canister purge valveShort circuit to ground
62Final stage, controlled canister purge valveShort circuit to UB / lead fracture
69Intake air temperature sensorShort circuit to ground
71Intake air temperature sensorShort circuit to ground / lead fracture
73Hot film mass air flow meterShort circuit to ground / lead fracture
74Hot film mass air flow meterShort circuit to UB
75AT transmission shift signalPulse duration too long
short circuit to ground
76AT transmission shift signalEngagement duration too long
81Injector 1Short circuit to ground
82Injector 2Short circuit to ground
83Injector 3Short circuit to ground
84Injector 4Short circuit to ground
87Final stage, compressor cutoff relayShort circuit to ground
88Final stage, compressor cutoff relayShod circuit to UB / lead fracture
91Oxygen sensor heatingShod circuit to UB / lead fracture
92Camshaft sensorShod circuit / lead fracture
98Oxygen sensor heatingShort circuit to ground