Contents Wiring diagrams Section: Fuel Injection Systems All sections

F1: Closed Loop Test - No. 03 O2 Sensor Opel Omega B

SIMTEC 56.1 EXHAUST TEST F1: CIRCUIT TEST

No.TECH 1 DisplayConditions for CheckingNominal ValueTrouble CodesTerminal
03O2 SENSOREngine running at idle speed, operating temperature13, 38, 39, 44,7, 19, 25, 45 36
Switch off all consumers

Note:

In contrast to the previously familiar Multec and Motronic systems, the voltage to the oxygen sensor in the SIMTEC system alternates in the range from approx. 0 to 5 V.Voltage change between less than 400 mV

and

greater than

3850 mV