Contents Wiring diagrams Section: Fuel Injection Systems All sections

F1: Closed Loop T - No. 03 O2 Sensor Opel Omega B

Table 9, Exhaust Emissions Test F1: CLOSED LOOP T

No.TECH 1 DisplayConditions for CheckingNominal ValueTrouble CodesTerminal
0302 SENSOREngine running at idle speed, operating temperature

Switch off all consumers

Note:

In contrast to the previous familiar Multec and Motronic systems, the oxygen sensor voltage in the SIMTEC system changes in a range from approx. 0 to 5 V.

Voltage change between less than 400 mV and greater than 3850 mV13, 38, 397, 25, 19, 36