Digital Diesel Electronics DDE 2.1 Quick Check F0: DATA LIST
| No. | TECH 1 Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 36 | MAX. FUEL QUANT. | Engine running at idle speed, operating temperature |
Switch off all consumers
Actuate accelerator pedal slightly
Note:
The value given here for the maximum injection quantity applies for an engine with the basic adjustment.
If a different value for the injection quantity has been programmed during the relevant TECH 1 adjustment, this parameter changes: for a smaller injection quantity, it is lower (to approx. 17 mg / stroke); for a larger injection quantity, it is higher (to approx. 21.5 mg / stroke).
Perform relevant TECH 1 adjustment (sect. 3. 4. 4. 2)
approx. 19.4 mg / stroke
| greater than 19.4 mg / stroke | 64 | - |