FO: DATA LIST
| No. | TECH 1 Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 18 | SEC. AIR PUMP REL | C 18 XE (without secondary air injection) |
X 20 XEV:
- Engine cold, engine running at idle speed, partial load, not full load
- Engine running at idle speed, operating temperature
Alternative check,
if engine is already warm:
- Engine warm, disconnect coolant temperature sensor
- Restart engine
| NOT USED |
ACTIVE
0 V
INACTIVE
12 V
ACTIVE
| 0 V | 46, 47 | 44, 41 |
Note: If the coolant temperature sensor is disconnected, a trouble code is set when the engine is switched off.
This must be deleted the next time the engine is started.
First check secondary air injection relay K12 with F5: ACTUATOR TEST, no. 07. If the results of this test are negative, proceed with troubleshooting as described below.
| Notes on Trouble - shooting: | Nominal Value: | Cause of Fault: |
Omega - B:
· Disconnect secondary air injection relay K12 from relay base. Ignition On.
| Using multimeter, measure voltage at relay base K12 to ground | ||
|---|---|---|
| - to Ter. 4 (Ter. 86) | greater than 11.5 V | · Interruption or short circuit to ground in lead connection from control unit K69 / Ter. 46 or from reverse battery protection relay K42 / Ter. 8 (Ter. 87) via plug connection X30 / Ter. 6 to secondary air injection relay K12 / Ter. 4 |
- to Ter. 8 (Ter. 87)
· Ignition Off. Disconnect wiring harness plug from control unit K69. Ignition On.
| Using multimeter, check connection between wiring harness plug K69 / Ter. 44 and relay base K12 / Ter. 6 (Ter. 85) | greater than 11.5 V | · Fuse F49 defective |
|---|---|---|
| · Interruption in lead from relay Kl 2 / Ter. 8 (Ter. 87) to + battery voltage |
- for passage,
- for short circuit to ground,
| - for short circuit to + battery voltage | Passage |
¥ W
| 0 V | · Interruption, short circuit to ground or to positive terminal in lead connection from control unit K69 / Ter. 44 via plug connection X 30 / Ter. 1 to secondary air injection relay K12 / Ter. 6 (Ter. 85) | |
|---|---|---|
| · Ignition Off. Using multimeter, measure voltage and resistance between relay base K12 / Ter. 2 (Ter. 30) and ground | 0 V, approx. 7 W | · Interruption or short circuit to ground or positive terminal in lead connection from relay base K12 / Ter. 2 (Ter. 30) to |
- secondary air injection solenoid valve Y15
- secondary air pump motor M27
· Interruption in lead connection from
- secondary air injection solenoid valve
- secondary air pump motor M27 to ground
Further possible faults:
Vectra / Cavatier, Calibra:
· Disconnect secondary air injection relay K12 from relay base. Ignition On.
| Using multimeter, measure voltage at relay base K12 to ground | · Secondary air injection relay K12 defective |
· Secondary air injection solenoid valve defective
| · Secondary air pump motor M27 defective | ||
|---|---|---|
| - to Ter. 4 (Ter. 86) | greater than 11.5 V | · Interruption or short circuit to ground in lead connection from control unit K69 / Ter. 46 or from fuel pump relay K68 / Ter. 8 (Ter. 87) via plug connection X57 to secondary air injection relay K 12 / Ter. 4 |
- an Kl. 8 (Kl.87)
Ignition Off. Disconnect wiring harness plug from control unit K69. Ignition On.
| Using multimeter, check connection between wiring harness plug K69 / Ter. 44 and relay base K12 / Ter. 6 (Ter. 85) | greater than 11.5 V | · Fuse F49 defective |
· Interruption in lead from relay Kl 2 / Ter. 8 (Ter. 87) to + battery voltage
- for passage,
- for short circuit to ground,
| - for short circuit to + battery voltage | Passage |
¥ W
| 0 V | · Interruption, short circuit to ground or to + battery voltage in lead connection from control unit K69 / Ter. 44 via plug connection X57 to secondary air injection relay K12 / Ter. 6 (Ter. 85) | |
|---|---|---|
| · Ignition Off. Using multimeter, measure voltage and resistance between relay base K12 / Ter. 2 (Ter. 30) and ground | 0 V, approx. 7 W | · Interruption or short circuit to ground or positive terminal in lead connection from relay base K12 / Ter. 2 (Ter. 30) to |
- secondary air injection solenoid valve Y15
- secondary air pump motor M27
· Interruption in lead connection from
- secondary air injection solenoid valve
- secondary air pump motor M27 to ground
| Further possible faults: | · Secondary air injection relay K12 defective |
· Secondary air injection solenoid valve defective
· Secondary air pump motor M27 defective