Trouble Code Table

Trouble CodeInformation SensorCause of Fault
12Start of diagnosis(Initialization OK)
14Sensor, coolant temperatureShort circuit
15Sensor, coolant temperatureInterruption / short circuit B+
19Engine speed signalFaulty
21Pedal position sensorShod circuit B+
22Pedal position sensorShort circuit to ground / interruption
23Pedal position sensorImplausible with idle accelerator switch
24Odometer sensorNo signal
31Engine speed signalMissing
33Exhaust gas recirculation valveDeviation in regulation
34Start of injection controlDeviation in regulation
37Brake lamp switchImplausible
38Clutch switchImplausible
39Anti - theft warning systemImplausible
41Charge pressure sensorShort circuit to ground interruption
39Charge pressure sensorShort circuit B+
39Charge pressure sensorImplausible with APS
39Charge pressure controlDeviation in regulation
48Supply voltageToo low
49Supply voltagetoo high
54Fuel cutoff solenoid valveDefective
55Control unitDefective
56Actual U_ calibration value for computer 1Implausible
57Actual U_ calibration value for computer 2Implausible
61Control valve position sensorShort circuit to ground B+ interruption
62Control valve position sensorImplausible with start of injection sensor
64Quantity actuatorImplausible
71Charge air temperature sensorShort circuit to ground
73Charge air temperature sensorShort circuit B+ / interruption
74Charge air temperature sensorShort circuit to ground
75Charge air temperature sensorShort circuit B+ / interruption
81Start of injection sensorShort circuit B+ / interruption
82Start of injection sensorShort circuit to ground
91Control switch for cruise controlShort circuit to ground
92Control switch for cruise controlShort circuit B+ / interruption
93Computer coupling 1 + 2Implausible
94Computer coupling 1 + 2Implausible
95Final stages1 or n defective