Checking Program CSD
| Test | Test Equipment | Test | Notes | Nominal | ||
|---|---|---|---|---|---|---|
| Step | Multimeter | |||||
| MKM - 587 - A | ||||||
| of | ||||||
| between | Value | |||||
| 01a | Ohmmeter range 20MW | Coolant temperature switch S108 (Frontera only) | S108, ter. 1 (component side) | ground | · Ignition "OFF" |
· Disconnect wiring harness plug from coolant temperature switch S108
| · Coolant temperature > 7 - 13 °C | approx. 0 W | |
|---|---|---|
| · Coolant temperature < 3 °C |
· Measurement at wiring harness plug
Note:
| Check the function of the coolant temperature switch S108 according to section 4.3 | > 20 MW | |
|---|---|---|
| Troubleshooting: | Nominal Value: | Cause of Fault: |
| · Coolant temperature switch S108 defective |