Starter, Check (Starter Installed)
Checking conditions:
Battery properly charged and connected to ground.
| .D. ICON06.tif | 0,75 | 0,75 | tiff;; Inspect |
Starter cable.
Correct connection to starter and to battery positive terminal, maximum permissible voltage loss in cable should not be greater than 0.5 volts when starting - measure voltage at starter terminal '50'.
If voltage loss is larger:
Contact parts of ignition lock, selector lever switch, plug connector.
Check for adequate contact.
Starter.
Connect Opel Tester - note service instructions.
Red connection clamp to positive terminal of battery.
Black connection clamp to negative terminal of battery.
Clamp - on probe to connecting lead between battery and starter - arrow on clamp - on probe must point away from battery.
Put into direct gear, apply service and parking brakes and activate starter (starter does not turn engine and blocks).
| .D. ICON11.tif | 0,75 | 0,75 | tiff;; Important! |
Maximum length of check: 5 seconds.
| .D. ICON07.tif | 0,75 | 0,75 | tiff;; Measure |
Voltage: approx. 8 V
Current consumption: approx. 410 A
Voltage too low: - localize voltage drop
Current consumption too high: - short circuit in starter
Current consumption too low: - collector dirty
- carbon brushes worn beyond limit
- ignition switch contact defective
- interruption
When current consumption is too high or too low - overhaul starter.