Starter, Check (installed)
| .D. ICON06.tif | 0,75 | 0,75 | tiff;; Inspect |
Battery:
Charged and ground connected.
Starter Cable:
Trouble - free connection to starter and to battery positive terminal, maximum permissible voltage loss in cable should not be greater than 0.5 volts when starting - measure voltage of starter clamps '50'.
If voltage loss is larger, check for adequate contact - contact parts of ignition lock, selector lever switch, plug connector.
Starter:
Connect Opel Tester - note service instructions:
Red connection clamp to positive terminal of battery.
Black connection clamp to negative terminal of battery.
Clamp - on probe to connecting lead between battery and starter - arrow on clamp - on probe must point away from battery.
Put into direct gear, apply foot and parking brakes and activate starter. Starter does not turn engine and blocks.
| .D. ICON11.tif | 0,75 | 0,75 | tiff;; Important! |
Maximum length of check 5 seconds.
| .D. ICON07.tif | 0,75 | 0,75 | tiff;; Measure |
Voltage, approx. 8 V
Current consumption, approx. 410 A
Voltage too low - localize voltage drop
Current consumption too high - short circuit in starter
Current consumption too low - collector dirty
- carbon brushes used up
- ignition switch contact defective
- interruption
When current consumption is too high or too low, overhaul starter.