Multec- S X 14 XE / X 16 XE (L) F0:DATA LIST
| No. | TECH 1 Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 13 | CLEAR FLOOD MODE | Ignition ON |
Engine OFF
| - | - |
|---|---|
| Engine throttle valve CLOSED |
(accelerator pedal in idle position)
| INACTIVE | ||
|---|---|---|
| Engine throttle valve OPEN | ||
| (accelerator pedal fully depressed) | ACTIVE | |
| Notes on Trouble-shooting: | Nominal Value: | Cause of fault: |
(If nominal value is not attained)
The lean mixture for starting mode is an internal value of the engine control unit.
The lean mixture cannot be checked with the engine running.
| · Check according to data list no. 05 TPS SIGNAL | Nominal values OK | · Remedy according to data list no. 05 TPS SIGNAL |