Multec- S X 14 XE / X 16 XE(L) F2:TROUBLE CODES
| Trouble Code | Information Sensor Cause of Fault | Remedy in F0:DATA LIST No. | Trouble Code Storage when... |
|---|---|---|---|
| 75 | TORQUE CONTROL VOLTAGE LOW | 48 | · The fault is recognised by the control unit if the torque control voltage signal at input Ter. E10 is low for longer than 10 s |
(short circuit to ground or circuit interruption)
or
· Incorrect signal from AT control unit:
The fault is recognised by the control unit if the torque control voltage signal is low for longer than 30 ms after shifting
Effects:
· The engine telltale is ON
| · The ignition is not retarded during AT shifting (rough shifting) |