Multec- S X 14 XE / X 16 XE (L) F0:DATA LIST
| No. | TECH 1 Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 32 | O2 BLM CELL NO. | Engine running at idle speed, operating temperature (MT only) | 18 or 19 | 13, 44, 45 | - |
| Engine running at idle speed, operating temperature (AT only) | |||||
| 20 or 21 | |||||
| Engine running in partial load range, operating temperature | 0 to 15 |
· This test step indicates in which the block learn cell number the system is operating. If an incorrect block learn cell number is displayed, check the following fault causes:
| Notes on Trouble-shooting: | Nominal Value: | Cause of fault: |
(If nominal value is not attained)
· Possible causes
| · Engine cold | |
|---|---|
| · Trouble code stored |
· Check following nominal values:
· TECH 1 data list no. 05
TPS SIGNAL
· TECH 1 data list no. 06
MAP SENSOR
· TECH 1 data list no. 07
COOLANT TEMP.
· TECH 1 data list no. 08
INTAKE AIR TEMP.
· TECH 1 data list no. 27
O2 SENSOR
| OK |
OK
OK
OK
OK
| · Remedy according to data list no. 05 |
TPS SIGNAL
· Remedy according to data list no. 06
MAP SENSOR
· Remedy according to data list no. 07
COOLANT TEMP.
· Remedy according to data list no. 08
INTAKE AIR TEMP.
· Remedy according to data list no. 27
O2 SENSOR
· Ignition OFF
· Disconnect wiring harness plug from:
K57 engine control unit
· Check control unit calibration, see field remedy measures
| Latest program memory (EPROM) according to field remedy measures or TIs | |
|---|---|
| · Replace program memory (EPROM) according to field remedy measures or TIs | |
| If nominal values are attained and latest program memory is installed | · K57 engine control unit defective |