Multec- S X 14 XE / X 16 XE (L) F0:DATA LIST
| No. | TECH 1 Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 37 | IDLE ADJUST | Vehicles with MT: |
Ignition ON
| Engine running at idle speed, operating temperature | - | - | |
|---|---|---|---|
| Nominal idle speed has not been changed (basic setting after control unit reset) | |||
| INACTIVE | |||
| Nominal idle speed has been programmed: | ACTIVE | ||
| Notes on Trouble-shooting: | Nominal Value: | Cause of fault: |
(If nominal value is not attained)
Not at start of production MY '95
| · Check according to data list no. 36, DES. IDLE ADJUST |