Multec-S X 14 XE / X 16 XE (L)5 F2:TROUBLE CODE TABLE
| Trouble Code | Information Sensor Cause of Fault | Remedy in F0:DATA LIST No. | Trouble Code Storage when ... |
|---|---|---|---|
| 41 | EST LINE COIL CYL 2+3 VOLTAGE HIGH | 14 | · System is not in TECH 1 diagnostic mode |
· Final stage diagnosis in control unit:
Incorrect voltage condition at output Ter. F14 of control unit
(ignition signal EST-B) is recognised 6 times (short circuit to voltage)
Effects:
· The injectors for cylinder pair 2-3 are switched off
· Oxygen sensor regulation is switched off, i.e. open oxygen sensor loop
· The engine telltale is ON
If trouble codes 41 and 42 are recognised simultaneously:
· Engine not running: The injectors for cylinder pairs 1-4 and 2-3 are switched off
· Engine running: Only the injector pair where the fault occurred first is switched off.