Multec-S X 14 XE / X 16 XE (L) F0:DATA LIST
| No. | TECH 1 Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 35 | DESIRED IDLE | ||||
| Ignition ON |
Engine running at idle speed, operating temperature
| Idle speed was not altered (basic adjustment after control unit reset) | - | - |
|---|---|---|
| X 14 XE / X 16 XE MT: | 900 rpm | |
| X 16 XEL MT: | 850 rpm | |
| X 14 XE AT: | ||
| Selector lever position "P" | ||
| 900 rpm | ||
| X 14 XE AT: |
Selector lever position "D"
| 775 rpm | ||
|---|---|---|
| Nominal idle speed has been programmed | ||
| X 14 XE | ||
| 850 to 950 rpm, except 900 rpm | ||
| X 16 XE: | ||
| 825 to 975 rpm, except 900 rpm | ||
| X 16 XEL: | ||
| 700 to 1000 rpm, except 850 rpm | ||
| X 14 XE AT: |
Selector lever position "P"
| 850 to 950 rpm, except 900 rpm | |
|---|---|
| X 14 XE AT: |
Selector lever position "D"
| 725 to 825 rpm, except 775 rpm | ||
|---|---|---|
| Note: | ||
| In AT vehicles, different values are indicated depending on the selector lever position. |