Multec-S X 14 XE / X 16 XE (L) F0:DATA LIST
| No. | TECH 1 Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 43 | IDLE AIR CONTROL | Engine running at idle speed, operating temperature |
Note:
| If a certain regulation range for the idle air adjuster is exceeded with the engine at operating temperature, the control unit automatically resets the stepper motor at engine speeds above 3000 rpm. | 8 to 35 steps | 35 | A1, A2, A3, A4 |