C-30, Torque Control Circuit
| C-30, Torque Control Circuit |
| Test | Work Order Description | Nominal Value |
| T01 | Check: Short to Ground/Interruption of Signal Circuit | |
| Disconnect wiring harness connector from: X26 Multec & Automatic Transmission Ignition ON Measure voltage between the following terminals: X26 Multec & Automatic Transmission Wiring Harness Connector (control unit side) Terminal A & Ground | greater than 11 V |
| Yes: T02 | No: E04 |
| T02 | Check: Short to Voltage of Signal Circuit | |
| Diagnostic Tester Data List Parameter TORQUE CONTROL | INACTIVE |
| Yes: T03 | No: E03 |
| T03 | Check: Component | |
| Connect fused jumper wire to: X26 Multec & Automatic Transmission Wiring Harness Connector (control unit side) Terminal A & Ground | ACTIVE |
| Yes: E01 | No: E02 |
| C-30, Torque Control Circuit |
| Result | Cause Of Fault |
| E01 | Short to voltage/ground/interruption of circuit between: X26 Multec & Automatic Transmission Wiring Harness Connector Terminal A & K85 Control Unit - Automatic Transmission Terminal 13 or Following system/component is faulty: K85 Control Unit - Automatic Transmission |
| |
| E02 | Defective component: K57 Control Unit - Multec |
| |
| E03 | Short circuit to voltage between: X26 Multec & Automatic Transmission Wiring Harness Connector (control unit side) Terminal A & K57 Control Unit - Multec Terminal C10 or Defective component: K57 Control Unit - Multec |
| |
| E04 | Short circuit to ground/interruption of circuit between: X26 Multec & Automatic Transmission Wiring Harness Connector (control unit side) Terminal A & K57 Control Unit - Multec Wiring Harness Connector Terminal C10 or Defective component: K57 Control Unit - Multec |
| |