Home/Opel/Tigra/Opel Tigra A (1995-2000)/Repair manual/Fuel Injection Systems/F0:Data List Test Step 36 Des. Idle Adjust
Contents Section: Fuel Injection Systems All sections

F0:Data List Test Step 36 Des. Idle Adjust Opel Tigra A

Multec- S X 14 XE / X 16 XE (L) F0:DATA LIST

No.TECH 1 DisplayConditions for CheckingNominal ValueTrouble CodesTerminal
36DES. IDLE ADJUSTVehicles with MT:

Ignition ON

Engine running at idle speed, operating temperature

Nominal idle speed has not been changed (basic setting after control unit reset)

--
X 14 XE / X 16 XE:900 rpm
X 16 XEL:850 rpm
Nominal idle speed has been programmed:

Note:

The nominal engine speed is a programmable value.

If F0:DATA LIST no.: 37 is ACTIVE, the nominal engine speed has been reprogrammed.

If F0:DATA LIST no.: 37 is INACTIVE, the nominal engine speed has not been altered or the control unit has been reset. In this case, ignore the TECH 1 display. A randomly selected value will be displayed.The nominal engine speed set in F6:Miscellaneous Tests, F0:Adjustments must appear in the display
Notes on Trouble-shooting:Nominal Value:Cause of fault:

(If nominal value is not attained)

Not at start of production MY '95

· Select TECH 1 menu:

F6:MISC. TESTS,

F0:ADJUSTMENTS

· Program new idle speed 950 rpm

· TECH 1 data list no. 37

IDLE ADJUST

· TECH 1 data list no. 36

DES. IDLE ADJUST

ACTIVE

950 rpm

· Check control unit calibration, see field remedy measures

· Select TECH 1 menu:

F6:MISC. TESTS,

F1:ECU RESET

· TECH 1 data list no. 37

IDLE ADJUST

· TECH 1 data list no. 36

DES. IDLE ADJUST

X 14 XE / X 16 XE:

X 16 XEL:INACTIVE

850 rpm

900 rpm· Check control unit calibration, see field remedy measures