Multec- S X 14 XE / X 16 XE (L) F0:DATA LIST
| No. | TECH 1 Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 46 | VEHICLE SP.PULSE | Ignition OFF |
Wait 10 s
| 24 | F10 | ||
|---|---|---|---|
| Ignition ON | |||
| Engine running at idle speed, operating temperature | NOT RECEIV | ||
| Slowly move vehicle at least 2 m/2 yards to and fro |
Note:
After the vehicle has been moved and is at a standstill again, it may happen that the TECH 1 display indicates a vehicle speed above 0 km/h
| (0 mph). This is not a fault, however, as the display is only updated again when the vehicle moves. | RECEIVED | |
|---|---|---|
| Notes on Trouble-shooting: | Nominal Value: | Cause of fault: |
(If nominal value is not attained)
| · Check according to data list no. 47 VEHICLE SPEED |