B-07, f7: Programming
| B-07, F7: PROGRAMMING | ||
|---|---|---|
| Test | Work Order Description | Nominal Value |
| T01 | Tester Display CONTROL MODULE | |
| Note: This programming is used to activate the security access in the control unit. The service programming SPS is only possible if the security access is armed in the control module. Ignition ON Engine OFF Press corresponding key in the system main menu to call up Programming functions, select the desired test and confirm with YES. Follow the instructions in the diagnostic tester display. Ignition OFF Wait at least 2 s Ignition ON Note: After the system is initialised, the programming of the security access is started. At the end of the test, the control unit is prepared for service programming SPS. | Programming okay? | |
| Concerned Terminals: - | ||
| Yes: T02 | No: C-02 |