Multec- S X 14 XE / X 16 XE (L) F0:DATA LIST
| No. | TECH 1 Display | Conditions for Checking | Nominal Value | Trouble Codes | Terminal |
|---|---|---|---|---|---|
| 35 | DESIRED IDLE | ||||
| Ignition ON |
Engine running at idle speed, operating temperature
| Nominal idle speed has not been changed (basic setting after control unit reset) | - | ||
|---|---|---|---|
| X 14 XE / X 16 XE MT: | 900 rpm | ||
| X 16 XEL MT: | 850 rpm | ||
| X 14 XE AT: | |||
| selector lever position "P" | 900 rpm | ||
| X 14 XE AT: | |||
| selector lever position "D" | 775 rpm | ||
| Nominal idle speed has been programmed: | |||
| X 14 XE: | 850 to 950 rpm, |
except 900 rpm
| X 16 XE: | |
|---|---|
| 825 to 975 rpm, |
except 900 rpm
| X 16 XEL: | |
|---|---|
| 700 to 1000 rpm, |
except 850 rpm
| X 14 XE AT: |
selector lever position "P"
| 850 to 950 rpm, | ||
|---|---|---|
| except 900 rpm | ||
| X 14 XE AT: |
selector lever position "D"
| 725 to 825 rpm, except 775 rpm | ||
|---|---|---|
| Note: | ||
| In vehicles with automatic transmission, different values are indicated depending on the selector lever position. |
Note:
DESIRED IDLE indicates the nominal idle speed depending on the engine / transmission combination and the operating conditions; e.g. the nominal idle speed is higher in the warm- up phase.
DESIRED IDLE is an internal value of the control unit and cannot be diagnosed.
| Notes on Trouble-shooting: | Nominal Value: | Cause of fault: |
(If nominal value is not attained)
· Check following nominal values:
· TECH 1 data list no. 32 O2 BLM CELL NO.
| OK |
|---|
| · Remedy according to data list no. 32 O2 BLM CELL NO. |
· Check control unit calibration, see field remedy measures
| Latest program memory (EPROM) according to field remedy measures or TIs | |
|---|---|
| · Replace program memory (EPROM) according to field remedy measures or TIs | |
| If nominal values are attained and latest program memory is installed | · K57 engine control unit defective |