Multec- S X 14 XE / X 16 XE(L) F2:TROUBLE CODES
| Trouble Code | Information Sensor Cause of Fault | Remedy in F0:DATA LIST No. | Trouble Code Storage when... |
|---|---|---|---|
| 18 | KNOCK FILTER MODULE | 15, 16, 18, 19, 20, 21 | · The control unit recognises a constant voltage condition at the knock module (cannot occur under normal operating conditions) |
· Above condition must be fulfilled for at least 4 s
Replacement value:
· RON 91 characteristic cell
Effects:
· The knock control is switched off
| or |
· The control unit tests the knock module under certain operating conditions:
he firing angles for cylinders 2 and 3 are advances 20 times by 0.7 °CA each time. The knock module must recognise at least one knock event.
· Following trouble codes not stored: 14, 15, 33, 34
· RON 91 characteristic cell not activated
· Engine speed lower than 5000 rpm
· Coolant temperature higher than 85 °C/185 °F but lower than 104 °C/219 °F
· Contents of long- term correction for active knock cell is 0 °CA
· Intake manifold absolute pressure lower than 9.8 Pa (98 mbar)
· Above conditions must be fulfilled for at least 15 s
| Replacement value: |
· RON 91 characteristic cell
Effects:
· The knock control is switched off
Note:
If trouble code 18 has been recognised, carry out the following instructions:
· Disconnect battery;
· Reconnect battery;
· Erase trouble code and read out trouble codes again;
· If trouble code 18 occurs again: check that knock module is correctly seated in base, if necessary, replace knock module;
· Erase trouble code and read out trouble codes again;
| · If trouble code 18 occurs again: replace control unit; |