Table 7, F7:PROGRAMMING
Note:
As there is only one control unit type available for both the X 20 SE engine (closed loop oxygen sensor circuit) and the 20 SE engine (open loop oxygen sensor circuit), and there is only one control unit type available for both the X 22 XE engine (closed loop oxygen sensor circuit) and the 22 XE engine (open loop oxygen sensor circuit), the control unit must be reprogrammed on installation or when transferred to a different vehicle. The programming specifies whether the engine is equipped with a closed loop or open loop oxygen sensor circuit.
This programming should be performed with TECH 1 according to the following instructions.